1-800-656-1095The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches).
Material: Stainless Steel #4 (Brushed Finish)
Insulation: 2" mineral wool
Hinge: Continuous piano hinge
Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included
Inside panel release: Included on all slam latch fire doors
Automatic panel closer: Standard on all doors
Finish: DuPont high quality white powder coat
Packaging: Individually wrapped, 1 per box
For installation in vertical wall assemblies:
Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48" x 48".
Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48" x 48".
For installation in horizontal ceiling assemblies:
With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24" x 36" or 864 sq inches (see note 1)
Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly.
Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10.
MEA # 507-06-M
Fire rated by Intertek - Warnock Hersey
The PFI access door can contribute directly to a project's ability to achieve LEED certification:
USA
CANADA
Note 1: Maximum door size 24" x 36" can also be calculated by multiplying the surface area of the door (24"x36"). The maximum surface area is 864 sq inches. The maximum height or width is 36". All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28" x 28" = 784 sq inches.